Studer Xtender 7000W 120A 48VDC Inverter Charger Online Shop Australia
The Xtender series provides unmatched freedom of use due to its many functions. In a basic application it offers a total package : the functions of inverter, battery charger, transfer system and assistance to the source. These functions can be combined and controlled in a totally automatic way for exceptional ease and optimal management of available energy.
The Xtender is equipped with a command entry and 2 configurable auxiliary contacts. This allows automatic control of a genset or a load shedding when the battery voltage is too low. This flexibility makes it possible to implement special functionalities necessary for a good energy management in standalone power systems.
Features
Outstanding efficiency and overload.
Perfect management and limitation of AC sources.
Power shaving of consumption peaks.
Active filtering of load steps on a genset.
Automatic protection of sources against overload.
Parallel and three-phase setting, up to 9 units (72kW).
Powerful multi-stage PFC charger.
Ultra-short transfer time (from 0 to 15ms max.)
Automatic and efficient stand-by
2 programmable auxiliary contacts (optional on the XTS)
Compatible with AC coupling
XTS electronically protected against reverse polarity
Display, programming and data logging via optional remote control.
RS-232 communication for remote monitoring.
Specifications
Model XTH 8000-48
Nominal Battery Volage 48V DC
Continuous Rated Power 7000W
Surge Rated Power 8000W (30 mins.) / 21000W (5 sec.)
Load Detection * (stand-by) 2 to 25W
Peak Efficiency 96%
Consumption (off/standby/on) 1.8W / 2.4W / 30W
Output Voltage * Pure Sine Wave 230VAC +/- 2%
Output Frequency * 50Hz +/- 0.05%
Harmonic Distortion < 2%
Overload & Short Circuit Protection Automatic Disconnect with 3 time restart attempt
Charge Characteristics * 6 Steps - Bulk / Absorption / Float / Equalisation / Reduced Float / Periodic Absorption
Max Charge Current * 120A
Temp. Compensation * With BTS-01 or BSP 500/1200
Input Voltage Range * 150 to 265Vac
Input Frequency 45 to 65Hz
Max Output Current 80A
Transfer Time < 15ms
Protection Index IP 20
Operating Temp Range -20 to 55 °C
Weight 46kg
Dimensions 230 x 300 x 500 mm
Warranty 5 Years
* Adjustable with the remote RCC-02 / RCC-03
Solar Online Australia
Unit 3, 301 Hillsborough Road
Warners Bay NSW 2282
Postal Address
PO Box 627
Cardiff NSW 2285
Telephone:
02 4954 3310 (Australia)
02 4954 4965 (Australia)
+61 2 4954 3310 (International)
+61 2 4954 4965 (International)
Facsimile:
02 4954 3360 (Australia)
+61 2 4954 3360 (International)
The Xtender is equipped with a command entry and 2 configurable auxiliary contacts. This allows automatic control of a genset or a load shedding when the battery voltage is too low. This flexibility makes it possible to implement special functionalities necessary for a good energy management in standalone power systems.
Features
Outstanding efficiency and overload.
Perfect management and limitation of AC sources.
Power shaving of consumption peaks.
Active filtering of load steps on a genset.
Automatic protection of sources against overload.
Parallel and three-phase setting, up to 9 units (72kW).
Powerful multi-stage PFC charger.
Ultra-short transfer time (from 0 to 15ms max.)
Automatic and efficient stand-by
2 programmable auxiliary contacts (optional on the XTS)
Compatible with AC coupling
XTS electronically protected against reverse polarity
Display, programming and data logging via optional remote control.
RS-232 communication for remote monitoring.
Specifications
Model XTH 8000-48
Nominal Battery Volage 48V DC
Continuous Rated Power 7000W
Surge Rated Power 8000W (30 mins.) / 21000W (5 sec.)
Load Detection * (stand-by) 2 to 25W
Peak Efficiency 96%
Consumption (off/standby/on) 1.8W / 2.4W / 30W
Output Voltage * Pure Sine Wave 230VAC +/- 2%
Output Frequency * 50Hz +/- 0.05%
Harmonic Distortion < 2%
Overload & Short Circuit Protection Automatic Disconnect with 3 time restart attempt
Charge Characteristics * 6 Steps - Bulk / Absorption / Float / Equalisation / Reduced Float / Periodic Absorption
Max Charge Current * 120A
Temp. Compensation * With BTS-01 or BSP 500/1200
Input Voltage Range * 150 to 265Vac
Input Frequency 45 to 65Hz
Max Output Current 80A
Transfer Time < 15ms
Protection Index IP 20
Operating Temp Range -20 to 55 °C
Weight 46kg
Dimensions 230 x 300 x 500 mm
Warranty 5 Years
* Adjustable with the remote RCC-02 / RCC-03
Solar Online Australia
Unit 3, 301 Hillsborough Road
Warners Bay NSW 2282
Postal Address
PO Box 627
Cardiff NSW 2285
Telephone:
02 4954 3310 (Australia)
02 4954 4965 (Australia)
+61 2 4954 3310 (International)
+61 2 4954 4965 (International)
Facsimile:
02 4954 3360 (Australia)
+61 2 4954 3360 (International)